INDIMEDO-SUPER-FAST DELIVERIES In
DELHI-NCR,
DELIVERIES ARE DONE ON THE SAME DAY!
SHOP NOW
×
Search for Medicines and Health Products
Login
Register
0
Your Cart is Empty!
Upload
Order Medicine
Search By Diseases/Prescription
Search By Medicines Name
Search By Manufacturer
Homeopathy
Drug
Women Care
Elderly Care
Baby Care
Skin Care
Hair Care
Oral Care
Healthcare Devices
Weight Management
Immunity Boosters
Nutritional Drinks
Vitamins & Supplements
Diabetes Care
Ayurveda
0
Login
Register
Category
Order Medicine
Personal Care
Medical Devices
Diet Nutrition
Diabetes
Sports Nutrition
Family Nutrition
Body Builders
Omegas
Search for Medicines and Health Products
FreeStyle Libre System - Sensor
₹5,249.00
₹5249
Manufacturer :
Abbott
Category :
Healthcare Devices
Availability :
In Stock
COUNT
1
-
+
Add To Cart
+Add More Medicine
Search Terms About Medicine:-
FreeStyle Libre System - Sensor
Products highlights
FreeStyle Libre System - Sensor FreeStyle Libre System - Sensor is an innovative sensor-based glucose monitoring system. Liberates diabetic patients from the hassles of routine finger-prick testing. It is an accurate, painless and easy to use system. Trend arrow indicates if glucose is going up, down or staying steady.
Delivery availability
Description
FreeStyle Libre System - Sensor is an innovative sensor-based glucose monitoring system. Liberates diabetic patients from the hassles of routine finger-prick testing. It is an accurate, painless and easy to use system. Trend arrow indicates if glucose is going up, down or staying steady. | Uses: It is used to measure glucose levels in the body. | Product Specifications and Features: The sensor has been tested to withstand immersion into one metre (3 ft) of water for up to 30 minutes It is also protected against the insertion of objects >12mm diameter (IP27) Trend arrow indicates if glucose levels have increased, decreased or are staying steady | Directions For Use: Select an area of skin on the back of your upper arm that generally stays flat during normal daily activities (no bending or folding). Avoid areas with moles, scarring or tattoos Choose a site that is at least 2.5cm (1 inch) away from an insulin injection site. To prevent discomfort or skin irritation, you should select a different site other than the one most recently used. Wash the chosen site with soap and allow the skin to fully dry, before applying the sensor Open the sensor pack by peeling off the lid completely. Unscrew the cap from the sensor applicator and set the cap aside. Line up the dark mark on the sensor applicator with the dark mark on the sensor pack. On a hard surface, press firmly down on the sensor applicator until it comes to a stop. Place the sensor applicator over the prepared site and push down firmly to apply the sensor to your body. Gently pull the sensor applicator away from your body. The sensor should now be attached to your skin The sensor glucose readings appear after you scan your sensor with the reader | For the alcohol wipe Tear the sachet open and remove the swab From the site of injection, briskly rub the skin in a circular motion, moving outward External use only Single-use only Discard after use Never use to disinfect an invasive medical device | Warning: Do not ignore symptoms that may be due to low or high blood glucose. If you have symptoms that do not match the sensor glucose reading or suspect that your reading may be inaccurate, check the reading by conducting a fingerstick test using a blood glucose meter. If you are experiencing symptoms that are not consistent with your glucose readings, consult your healthcare professional. | Safety Information: The sensor pack is sterile unless opened or damaged Store the sensor kit between 4C-25C. While you don’t need to keep the sensor kit in a refrigerator, you can as long as the refrigerator is between 4C-25C Do not freeze. Do not use if the expiry date has passed Interfering Substances: You can take standard doses of ascorbic acid (vitamin C) and still make treatment decisions with the sensor. Taking higher than the maximum recommended daily allowance (RDA) of ascorbic acid may affect the sensor readings and make them look higher than they really are The alcohol wipe is labelled as follows: reliject pre-injection swab | 1 swab |Use for skin cleansing prior to injection | Saturated with Isopropyl Alcohol 70% The FreeStyle Libre Flash Glucose Monitoring System (“System”) contains small parts that may be dangerous if swallowed Keep away from children Keep away from eyes If a swab makes contact, rinse with water In the event of skin irritation or rash, discontinue use Do not use after the expiry date Do not reuse The sensor must be removed prior to Magnetic Resonance Imaging (MRI)
Doctor's List
×
Search
×
Login with Facebook
Login with Google
Or Login With
Login
Send OTP
Forgot Password?
Don’t have an account?
Register
×
Forget Password
Send
Want to
Login?
Don’t have an account?
Register
×
Register with Facebook
Register with Google
Or Register With
Register
By continuing you agree to our
Terms and conditions.
Don’t have an account?
Login
×
Send